What does earthing actually do?
It gives fault current a path into the ground instead of through a person. It is the only protection that works the moment an appliance casing becomes live.
The third conductor in the installation, green and yellow. It takes no part in running any appliance and carries nothing at all in normal operation.
What happens without it
Picture a washing machine whose insulation has failed, so the live conductor touches the metal casing.
With earthing: the fault current flows straight to earth, the breaker or the RCD disconnects the circuit, and nobody notices anything except that the machine stopped.
Without earthing: nothing happens at all. The machine runs normally and the voltage on the casing waits. The first person to touch it becomes the path to ground.
That is the whole difference, and it is invisible until the day it matters.
Why the RCD needs it too
An RCD reacts to the difference between outgoing and returning current. If a casing goes live and there is no earth, nothing flows anywhere, so there is no difference and the RCD sits still.
It will still trip once a person touches the casing, and that is genuinely worth having. But it acts after contact rather than before it, which is why earthing and an RCD are not alternatives.
A wire is not proof
The green and yellow conductor may be present and connected to nothing. That is the single most common finding in flats where somebody has previously tidied up the wiring.
It cannot be checked with a test screwdriver, because an unconnected earth and a working one both read as dead. It is proven by measurement: loop impedance, electrode resistance, and continuity through each circuit, written down as numbers. What that involves is on the earthing page, and the symptoms of a bad one in signs of poor grounding.
What is never acceptable
Bonding earth to a water pipe, which used to be practice and stops working the moment a neighbour swaps a section for plastic. And joining earth to neutral inside a socket, which works until the neutral fails and then puts the full voltage on every appliance casing at once.
See also
RCD (residual current device)
A device in the consumer unit that cuts the supply when it detects current leaking to earth. It is the only protection that reacts when current passes through a person.
Schuko socket
Type F, known as Schuko: two round pins and two earthing clips on the sides. It takes the same plug as Germany, Austria, the Netherlands and most of continental Europe.
Consumer unit
The enclosure where the supply from the meter is split into circuits and where all the protection sits: main switch, RCD and breakers, in that order from left to right.
Mentioned in
More in: Protection
Now you know what it is. Need somebody to do it?
Send photos or call — you get an estimate before anyone travels.