Do I have single-phase or three-phase?
Single-phase is one live and neutral at 230 V, which covers almost everything in a flat. Three-phase is three lives with 400 V between them, needed for a cooker, larger motors and workshops.
Most flats in Belgrade are single-phase. Houses, shops and workshops usually are not, and knowing which you have decides what you can install.
The difference
A single-phase supply brings one live conductor and one neutral. Between them there is 230 V, and that runs lighting, sockets, a water heater and an air conditioner without trouble.
A three-phase supply brings three live conductors, each at 230 V to neutral, but 400 V between any two of them. That higher voltage is what larger equipment is built for.
How to tell
Open the consumer unit and look at the main switch. One or two modules with a single cable in means single-phase. A wider main switch with three cables coming in means three phases.
The meter says the same thing, and so does the contract with the distributor.
What genuinely needs it
An electric cooker with all its rings and an oven, which is the classic reason. Motors above roughly 2 kW, which is most workshop machinery. Compressors, larger pumps, lifts. Anything with a nameplate marked 400 V.
An ordinary flat with an induction hob is a borderline case: it works on a single phase, but the load has to be planned rather than assumed.
The problem nobody sees
When three phases are present, the load should be spread evenly across them. In practice it rarely is: over the years circuits get added to whichever phase was convenient, and one ends up carrying far more than the other two.
That shows up as a breaker tripping on one phase while the other two idle, and as voltage dropping on that phase under load. It is the most common hidden fault in shops and workshops, and the easiest to fix once it has been measured. That is part of the work covered under industrial installations.
Converting a flat
This is not a question of the board but of the connection and the contract with the distributor. Reworking the board comes second, after approval, and is then a consumer unit upgrade with a new main switch and a redistribution of circuits.
See also
Consumer unit
The enclosure where the supply from the meter is split into circuits and where all the protection sits: main switch, RCD and breakers, in that order from left to right.
Cable cross-section
The cross-sectional area of one conductor in square millimetres. It sets how much current the cable may carry, and therefore which breaker goes in front of it.
Circuit breaker
The cable in the wall, not the appliance. It cuts the circuit when more current flows through it than the cable can carry without overheating.
More in: Installation
Now you know what it is. Need somebody to do it?
Send photos or call — you get an estimate before anyone travels.